Sensitivity to change of the field-based Wheelchair Mobility Performance Test in wheelchair basketball
Sensitivity to change of the field-based Wheelchair Mobility Performance Test in wheelchair basketball
Samenvatting
In this study we measured the performance times on the Wheelchair Mobility Performance (WMP) test during different test conditions to see if the performance times changed when wheelchair settings were changed. The overall performance time on the WMP test increased when the tire pressure was reduced and also when extra mass was attached to the wheelchair. It can be concluded that the WMP test is sensitive to changes in wheelchair settings. It is recommended to use this field-based test in further research to investigate the effect of wheelchair settings on mobility performance time.
Objective: The Wheelchair Mobility Performance (WMP) test is a reliable and valid measure to assess mobility performance in wheelchair basketball. The aim of this study was to examine the sensitivity to change of the WMP test by manipulating wheelchair configurations.
Methods: Sixteen wheelchair basketball players performed the WMP test 3 times in their own wheelchair: (i) without adjustments (“control condition”); (ii) with 10 kg additional mass (“weighted condition”); and (iii) with 50% reduced tyre pressure (“tyre condition”). The outcome measure was time (s). If paired t-tests were significant (p
Organisatie | De Haagse Hogeschool |
Afdeling | Faculteit Gezondheid, Voeding & Sport |
Lectoraat | Lectoraat Revalidatie en Technologie |
Gepubliceerd in | Journal of Rehabilitation Medicine Foundation of Rehabilitation Information, Uppsala, Uitgave: 50, Pagina's: 556-562 |
Datum | 2018-05-08 |
Type | Artikel |
DOI | 10.2340/16501977-2341 |
Taal | Engels |